Test Results Summary: Nova iUVC222 Far-UVC 222nm Disinfection Lamp
The UVC Sterilizer Swing (DF28B-B3 20W lamp) has been tested for both safety and disinfection performance by Thai institutions. The results were reviewed by the Office of the Consumer Protection Board (OCPB, meeting no. 16/2564), and the product is listed on the Thai Innovation List under code 14000062.
| Test | Testing institution | Result |
|---|---|---|
| Eye and skin photobiological safety (IEC 62471:2006, clause 4.3.1) | Electrical and Electronic Products Testing Center (PTEC), NSTDA | Passed |
| UVC disinfection performance | Electrical and Electronic Products Testing Center (PTEC), NSTDA | Passed |
| Airborne pathogenic bacteria reduction (31.10 m² room, lamp mounted at 2.4 m) | Center of Excellence for Antibody Research (CEAR), Faculty of Tropical Medicine, Mahidol University | Within 5–20 seconds: S. aureus reduced 10.21–73%, K. pneumoniae 36.1–75.2%, P. aeruginosa 28.2–87.5% |
| African swine fever virus (ASF) | Virology Section, National Institute of Animal Health, Department of Livestock Development | At 100 cm, at least 5 minutes of exposure achieved a 3-log (99.9%) reduction |
| 222nm UVC distribution (14 x 10 m room) | Science and Technology Research Institute, Chiang Mai University | Uniform irradiation; average 43.51–1.16 µW/cm² at 1–10 m |
| Field test on pig pen walls | Thai Innovation List supporting data | Total bacteria fell from 2.5×106 to 3.3×102 CFU/100 cm² after 60 minutes and were not detected after 120 minutes |
Download the Thai Innovation List document (PDF, Thai) Request full test reports
Original Test Reports
Click an image to view the full document.